Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Motriz rev. educ. fís. (Impr.) ; 22(3): 133-137, July-Sept. 2016. Ilus
Article in English | LILACS | ID: lil-789093

ABSTRACT

One of the approaches to evaluate injury prediction is the hamstrings-to-quadriceps peak torque conventional ratio (H:Q ratio). The gold standard for assessment of muscle strength in vivo is by isokinetic dynamometry; however, the one-repetition maximum strength test (1-RM) presents high correlation with isokinetic data. This study aimed to compare measures of H:Q ratio in young adults obtained by dynamometry and 1-RM testing. No significant differences were observed in the H:Q ratio when comparing 1-RM and dynamometry testing. However, there was a significant and strong correlation between the measurements obtained in the two tests. Despite this correlation, data from both tests are not equal as the H:Q ratio obtained from 1-RM test presents a systematic error. Nonetheless, the results can enhance the applicability of 1-RM test in clinical settings


Subject(s)
Humans , Male , Female , Adult , Young Adult , Wounds and Injuries/prevention & control , Muscle Strength/physiology , Muscle Strength Dynamometer/statistics & numerical data
2.
Fisioter. mov ; 25(2): 301-309, abr.-jun. 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-640242

ABSTRACT

Introdução: A utilização de medidas confiáveis e práticas são necessárias para a tomada de decisões clínicas.O Teste da Queda do Navicular (TQN) fornece informações importantes na avaliação dos membros inferiores. Assim, os objetivos do presente estudo foram verificar a confiabilidade do TQN, conforme realizado na clínica, e analisar uma forma de minimizar a interferência do avaliador. Materiais e métodos: Participaram do estudo 15 indivíduos (30 pés), selecionados por conveniência. O TQN foi aplicado de forma independente por dois examinadores experientes na realização do teste, o qual foi realizado apenas uma vez em cada pé, utilizando-se um paquímetro de plástico. Foi realizada uma análise descritiva dos dados. Para avaliação da confiabilidade inter examinadores, foi utilizado o índice de correlação intraclasse (ICC₂,₁) e a discrepância das medidas entre avaliadores foi analisada pelo erro típico da medição. Resultados: A média e o desvio padrão para o primeiro e segundo examinador foram 8,7 ± 5,3 e 9,7 ± 4,7 milímetros. O teste apresentou excelente confiabilidade interexaminador (ICC = 0,93). O erro típico da medição foi 2,16 milímetros. Conclusão: Os procedimentos para minimizar a interferência do avaliador resultaram, contraditoriamente, em uma piora dos índices de confiabilidade. O TQN pode ser simplificado por meio do uso de instrumentos comuns na clínica e registrado a partir de uma única medida. Mesmo apresentando boa confiabilidade, o TQN apresenta um erro típico da medida, que deve ser levado em consideração para a tomada de decisão. Mudanças no teste, por vezes necessárias em um ambiente clínico, deverão ser analisadas quanto à conservação de suas propriedades


INTRODUCTION: Reliable and practical measures are necessary for making clinical decisions. The Navicular Drop Test (NDT) provides important information during evaluation of lower limbs. The purpose of the present article was to assess the psychometric properties of NDT as usually done in clinical environment, and to analyze a way to minimize the evaluator interference. MATERIALS AND METHODS: Fifteen people (30 feet), selected by convenience, participated. The NDT was performed independently by two investigators experienced in the test realization. The test was performed once in each foot, using a plastic caliper. Descriptive analysis of data was done. In order to evaluate the inter-examiner reliability, intraclass correlation index (ICC2,1) was used. The divergence between the measures was examined by the typical error measurement. RESULTS: The mean and standard deviation for the first and second examiner was 8.7 ± 5.3 and 9.7 ± 4.7 mm. The test showed excellent inter-examiner reliability (ICC = 0.93). The typical error of measurement was 2.16 mm. CONCLUSION: The procedures to minimize the interference of evaluator, paradoxically, showed worse indices of reliability. The NDT can be simplified by using common clinical tools and recorded from a single measure. Even though it showed a good reliability, the NDT contains a typical error of measurement which has to be considered for decision making. Changes in the test, sometimes required in a dynamic clinical environment, should be analyzed for maintenance of test properties.


Subject(s)
Humans , Male , Female , Accidental Falls , Foot , Lower Extremity , Physical Examination
3.
Rev. bras. med. esporte ; 17(2): 111-114, mar.-abr. 2011. tab
Article in Portuguese | LILACS | ID: lil-591375

ABSTRACT

A razão de força entre agonista/antagonista fornece informação significativa sobre o equilíbrio muscular sendo importante na detecção de alterações musculoesqueléticas, na orientação de medidas preventivas e na implementação de programas de treinamento específicos. A dinamometria isocinética fornece valores fidedignos sobre o torque gerado e, subsequentemente, sobre a razão de força entre flexores e extensores. Porém, trata-se de um método pouco acessível. Uma possível alternativa para avaliação de força é o teste de uma repetição máxima (1-RM), que é o mais utilizado para avaliação da força dinâmica. Contudo, não existem na literatura trabalhos que tenham utilizado o teste de 1-RM para quantificação da razão entre flexores e extensores de joelho. O objetivo deste estudo foi utilizar o teste de 1-RM na mensuração da razão entre flexores e extensores de joelho em adultos jovens, a fim de encontrar dados normativos. A amostra foi composta por 80 adultos jovens (com média de idade de 22,7 ± 3,40 anos), sendo 40 homens e 40 mulheres, sem lesões osteomioarticulares, que foram submetidos à aplicação do IPAQ-curto, pesagem e predição de 1-RM, aquecimento, teste de 1-RM unilateralmente nos bancos flexor e extensor e posterior análise de dados. Foram encontrados valores de razão agonista/antagonista de 52,34 por cento (±9,72) para homens e 43,19 por cento (±5,82) para mulheres (havendo uma diferença significativa entre os grupos). Valores de referência quanto à razão dos flexores e extensores de joelho utilizando o teste de 1-RM em adultos jovens foram encontrados, podendo servir como referência para indivíduos assintomáticos nessa faixa etária.


Force ratio between agonist and antagonist muscles provides significant information about muscular equilibrium, which helps to detect musculoskeletal changes and to guide preventive and rehabilitation programs. Isokinetic dynamometry provides reliable values for muscle torque and subsequently on the force ratio between knee flexors and extensors. However, this method is not clinically accessible. A possible alternative to evaluate this force is the One-Repetition Maximum test (One-Rep Max or just 1-RM), which is the most commonly used test for dynamic force assessment. However, there is no report in the literature of the use of 1-RM test for the quantification of knee flexors and extensors ratio. For this reason, the objective of this study was to use the 1-RM test to measure the ratio between knee extensors and flexors in young adults in order to find reference values. The studied sample was composed of 80 young adults (40 men and 40 women), mean age of 22.21 (±3.58) years with no musculoskeletal injuries. They were submitted to the following procedure: IPAQ-short version, weighing and prognostic of 1-RM, warm-up, and unilateral 1-RM test (at the flexor and extensor machine). After the test application, the data were analyzed and the mean values for the ratio between agonist/antagonist found were 52.34 percent (±9.72) for men and 43.19 percent (±5.82) for women (which were significantly different between groups). The values found in the present study may be used as reference for asymptomatic individuals with similar age.


Subject(s)
Humans , Male , Female , Young Adult , Knee Joint/physiology , Knee Joint , Muscle Strength Dynamometer , Muscles/physiology , Quadriceps Muscle , Reference Values , Torque
SELECTION OF CITATIONS
SEARCH DETAIL